RESET® Air for Core & Shell
The following section lists a summary of the changes that have been made to each standard document.
For download links, click here.
For a list of all the Change Log pages, click here.
RESET Air Standard for Core & Shell
Summary of Updates made for the RESET Air Standard for Core & Shell from v2.0 to v2.1:
- Officially introduces Trust & Transparency Score.
- Officially introduces Alternative Pathways.
- Introducing option to set Definable Targets for a project.
- Introducing option to use Non-Accredited Monitors.
- Introducing additional monitor installation options.
- Re-wrote introduction section.
- Re-ordered and cleaned up Monitoring Station Deployment Requirements.
- Removed Partial Certification.
- Cleaned up text and removed extraneous words and explanations.
For a complete change log of the document, please click here.
Page by Page Updates
Table of Contents
- Removed “TM” from all instances of RESET
- Changed "Certification Approach" to “Purpose and Approach”
- Added "Structure and Requirements"
- Changed "Data Analysis Algorithm" to "Data Interval and Data Analysis Algorithm"
- Changed "Steps for Calculating Monitor Deployment" to "Monitoring Station Deployment Requirements"
- Added "Trust & Transparency Score"
- Added "Alternative Pathways"
2.4.0 Preface
- Cleaned and Updated Text
2.4.1 Introduction
- New page: Introduction
- What is RESET Air Standard for Core & Shell? (High-level Concept)
- What does it define? (Summary)
2.4.1.1 Purpose & Approach
- Purpose: What is the RESET Air Standard for Core & Shell for? To establish guidelines and rules for RESET Air Projects
- What is the approach? Performance-based, continuous monitoring data collection, non-prescriptive, and for New or Existing built environments
2.4.1.2 Typologies and Usage
- New page describing the two Typologies and how they are used
- Added Description of the two different standards (Interiors and Core & Shell)
- Added relationship between tenant and landlord
2.4.2 Performance Targets & Data Analysis
- Added Description of the two different standards (Interiors and Core & Shell)
- New summary page for Performance Targets and Data Analysis
2.4.2.1 Indoor Air Quality Performance Targets
- Updated text
2.4.2.2 Adding Optional Parameters
- New page introducing the ability to include Optional Air Quality Parameters into projects
- Added Air flow velocity added for induct monitors
2.4.2.3 Data Interval and Data Analysis Algorithm
- Updated text
- Text describing that Performance Targets act as thresholds in the data analysis algorithm
2.4.3 System Requirements for Data Collection
- New summary page for data provider and monitor requirements
- Text describing continuous monitoring requirements for data providers and monitors and how it connects to the RESET Cloud
2.4.3.1 Data Provider Requirements
- Updated text
- Text describing that Performance Targets act as thresholds in the data analysis algorithm
- Added a link to the RESET Directory
2.4.3.2 Monitor Requirements
- Simplified to not include Grade A and Grade C
- Added a link to the RESET Directory
2.4.4 Monitor Installation and Deployment
- New summary page for monitor installation and deployment
- Describe Monitor Installation and Monitor Deployment requirements
2.4.4.1 Outdoor Monitor Installation Requirements
- Updated text
- Added that the monitors should be in the breathing zone, measured from the center of the monitor
2.4.4.2 Induct Monitor Installation Requirements
- Updated text
2.4.4.2 Monitoring Station Deployment Requirements
- Cleaned up text
- Consolidated to first Calculation, then Deployment
- Updated Text around project boundary
- Clear up explanation on the sample project and its project boundary
- Provide an example on the flexibility of project boundaries
- Separated the calculations to a second page. Kept this page to simple concepts for Total Air Volume Calculation
- New page to help visualize the Total Air Volume Calculation step
- Added text describing and summarizing the requirements for outdoor monitor deployment
- Added letters to distinguish between the 5 different options for outdoor monitor deployment
- Added option e., which reflects how a project will only need one outdoor monitor if only one induct monitor was necessary
- Added an explanation of the logic of how to deploy the outdoor monitors
- An added note describing why the lower level air intake will likely have the worst outdoor air quality
- Added an explanation of the logic of how to deploy the outdoor monitors
- An added note describing why the lower level air intake will likely have the worst outdoor air quality
- Added text describing and summarizing the requirements for induct monitor deployment
- Added calculations to help highlight why only 1 induct monitor is needed
2.4.5 Certification Requirements and Process
- Introduces the different Audits
- Introduces the different project statuses
2.4.6 Trust & Transparency Score
- Introducing Trust & Transparency Score
- Needs to add link to the TT Score page on the RESET Website
2.4.7 Alternative Pathways
- Introducing Alternative Pathways officially
- How to introduce new Alternative Pathways
2.4.7.1 Definable Targets
- Alternative Pathway to establish performance targets
2.4.7.2 Using Non-Accredited Monitors
- Alternative Pathway for using non-accredited monitors
2.4.7.3 Outdoor Monitor Installation Distance Options
- Alternative Pathway for outdoor monitor distance
2.4.7.4 Outdoor Monitor Accreditation Options
- Official language around requirements for outdoor air monitors
2.4.7.5 Alternative Target Monitoring Volume
- Alternative options for amount of total air volume being monitored
2.4.8 Glossary
- Cover page for Glossary
- Cleaned up text